Hot work shall not be performed in a confined space until a designated person has tested the atmosphere and determined that it is not hazardous. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. Some of the rules apply to dangerous jobs like hot worksuch as welding and cuttingrequired for activities as diverse as bio-pharmacy, food production, nuclear power generation, and aviation. 0000008494 00000 n
Before heat is applied to a drum, container or hollow structure, an opening to release built-up pressure during heat application shall be provided. 0000007177 00000 n
Version Date Comments 5 March, 2012 Revised document 6 June, 2015 Update code citation - SFPC 2012 A. 1926.1205 (c) 1926.1406 - Assembly/Disassemblyemployer procedures--general requirements. Structures or pipelines forming a temporary ground return circuit shall have electrical contact at all joints. Hit the arrow with the inscription Next to move from field to field. 0000014709 00000 n
1926.350 Gas Welding and Cutting 1926.350 (a) Transporting, Moving, and Storing Compressed Gas Cylinders 1926.350 (a) (1) Valve protection caps shall be in place and secured. 0000003987 00000 n
1926.50 App A - Medical services and first aid. Arc welding and cutting cables shall be insulated, flexible and capable of handling the maximum current required by the operations, taking into account the duty cycles. The entry permit that documents compliance with this section and authorizes entry to a permit space must identify: The date and the authorized duration of the entry permit; The authorized entrants within the permit space, by name or by such other means (for example, through the use of rosters or tracking systems) as will enable the attendant to determine quickly and accurately, for the duration of the permit, which authorized entrants are inside the permit space;
}m?"Qwk&Ubm5"W`K`!xC_[2Vk"e,X,bYGv`[=. A sign reading "DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER" or using other similar language would satisfy the requirement for a sign. An OSHA "permit" is an employer-created and signed document that details the safeguards in place to protect an employee who's been assigned a particularly dangerous job function like working in a confined space, welding and cutting, or working on "live" electrical equipment. 14 of 1950. 1926.502 - Fall protection systems criteria and practices. Includes how employers must control respiratory hazards in the space; testing the internal atmosphere; and what to document for each entry. 1926.23 - First aid and medical attention. 0000015110 00000 n
H\0vFBHdGa} NicCyri]]malq~6!{9Ui^vvr]||f=mq{w|6>MiL*Wo0?^t_2W4Mmc.>}Sd>W6fN. 0000054149 00000 n
Before an employee enters the space, the internal atmosphere must be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. ___ Smoke detectors in the area of hot work have been covered to prevent false alarms. Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. 1926 Subpart R App C - Illustrations of Bridging Terminus Points: Non-Mandatory Guidlines for Complying with 1926.757(a)(10) and 1926.757(c)(5). To the extent possible, hot work shall be performed in designated locations that are free of fire hazards. The tips below can help you fill out Osha Hot Work Permit Form Pdf easily and quickly: Open the template in the full-fledged online editor by hitting Get form. Suitable fire extinguishing equipment shall be immediately available in the work area and shall be maintained in a state of readiness for instant use. Hot work means any activity in which flame, heat, or spark is generated. Permits usu-ally are valid only for the length of the working shift; but never more than 24 hours. Those measures can include, but are not limited to, the lockout or tagging of equipment and procedures for purging, inerting, ventilating, and flushing permit spaces. 1917.152 (c) (3) 0000001616 00000 n
1926.1437 - Floating cranes/derricks and land cranes/derricks on barges. The Hot Work Permit is key to managing hot and preventing fires. 1926.104 - Safety belts, lifelines, and lanyards. (1378.96 kPa) before reuse. Hose connections shall be clamped or securely fastened to withstand twice the normal working pressure but not less than 300 p.s.i. 1926.854 - Removal of walls, masonry sections, and chimneys. In the U.S., the Occupational Safety and Health Administration (OSHA) is the source of many rules and guidelines intended to protect workers from job-related hazards across virtually all industries. Hot work areas shall not be less than 35 feet from combustible materials and combustible waste 0000008381 00000 n
They shall not be placed in a location where they would be subject to open flame, hot metal, or other sources of artificial heat. 1926.151 Fire prevention. 0000041672 00000 n
1926.107 - Definitions applicable to this subpart. 1926.350 (a) (1) Valve protection caps shall be in place and secured. For manifolded or coupled cylinders, at least one wrench shall be immediately available. 0000018041 00000 n
Fuel gas shall not be used from cylinders through torches or other devices which are equipped with shutoff valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold. 1926.1102 - Coal tar pitch volatiles; interpretation of term. Structures or pipelines acting continuously as ground return circuits shall have joints bonded and maintained to ensure that no electrolysis or fire hazard exists. When entrance covers are removed, the opening must be immediately guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space. Articles from Wex Table of Popular Names Parallel Table of Authorities 1926.650 - Scope, application, and definitions applicable to this subpart. Nothing shall be placed on top of a manifold, when in use, which will damage the manifold or interfere with the quick closing of the valves. If hazards arise within a permit space that has been reclassified as a non-permit space under paragraph (g) of this section, each employee in the space must exit the space. A space classified by an employer as a permit-required confined space may only be reclassified as a non-permit confined space when a competent person determines that all of the applicable requirements in paragraphs (g)(1) through (4) of this section have been met: If the permit space poses no actual or potential atmospheric hazards and if all hazards within the space are eliminated or isolated without entry into the space (unless the employer can demonstrate that doing so without entry is infeasible), the permit space may be reclassified as a non-permit confined space for as long as the non-atmospheric hazards remain eliminated or isolated; The entry employer must eliminate or isolate the hazards without entering the space, unless it can demonstrate that this is infeasible. %PDF-1.7
%
1926.305 - Jacks-lever and ratchet, screw, and hydraulic. OSHA 300 Log of Work-Related Fatalities, Injuries and Illness. Ventilation and employee protection in welding, cutting and heating -. Highlights Oregon OSHA's additional confined space requirements (effective Sept. 1, 2022); describes employers' role in evaluating welding operations in a confined or permit space that is potentially hazardous. The OSHA 300 Log must be maintained by employers unless there is an exemption, based on the NAICS code or the size of . The precautions that the host employer, controlling contractor, or other entry employers implemented for the protection of employees in the permit spaces. 1926.552 - Material hoists, personnel hoists, and elevators. 1926.405 - Wiring methods, components, and equipment for general use. 0000019967 00000 n
Getting a hot work permit before performing hot work is just one of steps involved in a hot work . Oxygen and fuel gas hoses shall not be interchangeable. If a plug or safety device leaks, the cylinder shall be tagged, removed from service, and moved to a location where the leak will not be hazardous. A designated person shall test the atmosphere and determine that it is not hazardous before hot work is performed on or in such structures. Before entry operations begin, the host employer must provide the following information, if it has it, to the controlling contractor: The hazards or potential hazards in each space or the reason it is a permit space; and. Training. The controlling contractor and entry employer(s) must coordinate entry operations when: More than one entity performs permit space entry at the same time; or. 0000054473 00000 n
Oregon OSHA provides a variety of publications, including; guide books, brochures, forms, hazard alerts, fact sheets, posters, cards, stickers, reports, and checklists on a variety of workplace health and safety topics. Gas hose storage boxes shall be ventilated. The controlling contractor must apprise the host employer of the information exchanged with the entry entities pursuant to this subparagraph. Hot Work Procedures and Permits (a) Scope and application. The control apparatus of arc welding machines shall be enclosed, except for operating wheels, levers, and handles. 1926.851 - Stairs, passageways, and ladders. Where practicable all combustibles shall be relocated at least 35 feet from the work site. 0000005574 00000 n
When cylinders are hoisted, they shall be secured on a cradle, slingboard, or pallet. If, when the valve on a fuel gas cylinder is opened, there is found to be a leak around the valve stem, the valve shall be closed and the gland nut tightened. When hot work must be performed in a location that is not free of fire hazards, all necessary precautions shall be taken to confine heat, sparks, and slag so that they cannot contact flammable or combustible material. 1926.1409 - Power line safety (over 350 kV). Fuel gas and oxygen manifolds shall be placed in safe, well ventilated, and accessible locations. Areas can be protected with the use of welding pads, blankets, or curtains, clearing combustibles from a 35-ft (11-m) radius space around the hot work, or moving the hot work to an area free of combustibles. Fuel gas shall be used only as follows: Before regulators are connected to cylinder valves, the valves shall be opened slightly (cracked) and closed immediately to clear away dust or dirt. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. 1926.450 - Scope, application and definitions applicable to this subpart.